FM Transmitter Measurement Report
Created: 2026-05-06 06-58-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 60 dBuV P3 SR
Pilot RDS Phase Difference
5.7 kHz 2.0 kHz -18 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 33 kHz 18918 0,0106
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-3,5 dBr -2,19 dBr -0,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P3 SR " E203 12 (Easy M) 0 1 1 9 5:58, 6.05.2026
RT
"Vaken med Robert Frank och Frida Tranvik "
AF EON
97.9, 99.0, 99.4, 100.5 MHz E224, E201, E402, E424
FM Scope Max at: 33 kHz MIN: 11 kHz % above 76 kHz: 0,0106 Acquired: 2026/05/06 6.57.15 Total samples: 18918 Equivalent time: 0:15:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -0,7 dBr MIN: -3,5 dBr AVE: -2,19 dBr % above 12,2 dBr: 0,0 Last value: -1,9 dBr (2026/05/06 6.57.15) 06.44 06.46 06.48 06.50 06.52 06.54 06.56 -4 -3 -2 -1 0 1 Pm [dBr]